YMC-UltraHT Pro C18 / YMC-Pack Pro C18 層析管柱

使用HPLC進行分析時,選擇YMC-Pack Pro C18層析管柱可用於分析困難之化合物,由於其使用嚴格品質控制的高純度矽膠、高覆蓋率(high-coverage)的C18鍵結,並採用獨特的封端(endcapping)步驟(utilizing Lewis acid-Lewis base chemistry) 。 另外針對高速(high-speed)和高通量(high throughput)分析,我們有專門設計2μm粒徑YMC-UltraHT系列。
由於以上特點,YMC-Pack Pro C18為各種類型的有機分子—尤其是鹼性藥物(basic pharmaceuticals)和螯合(chelating )化合物,提供了無與倫比的分離峰尖(sharp)及對稱(symmetrical)的峰型。

SPECIFICATION
Particle size 2 µm,3 µm,5 µm,10 µm
Pore size 120 Å
Carbon contents 16%
Usable pH range 2.0-8.0
USP L1

POINTS

■ High performance, reproducible, reliable columns designed for the most demanded HPLC
■ Made with highly inert, ultrapure, pH neutral silica
■ Extremely rigorous physical and chemical specifications
■ Novel Lewis acid/Lewis base endcapping -Very high efficiency columns, typically 100,000 to 120,000 plates/metre for 5µm and 130,000 to 150,000 plates/metre for 3µm packings
■ Continues YMC proven batch-to-batch and column-to-column reproducibility

Features

Effective for separation of basic compounds

Tricyclic antidepressants

1. Desipramine hydrochloride
2. Acenaphthene(I.S.)
3. Imipramine hydrochloride
4. Amitriptyline hydrochloride

Basic peptides

Basic peptides

1. Bradykinin
2. Dynorphin A (Human,1-13)
3. Eledoisin related peptide
4. Neurotensin
5. Bombesin
6. Substance P

Neutral peptides

Neutral peptides

1. Oxytocin
2. Met-Enkephalin
3. Leu-Enkephalin
4. Angiotensin I
5. α-Mating factor
6. Insulin

YMC-Pack Pro C18 is manufactured with a unique endcapping procedure and provides excellent peak symmetry for Basic peptides and equal separation performance for neutral peptides compared with ODS-A.

batch-to-batch Reproducibility of the above three lots

Excellent reproducibility for separation of hydrophobic, hydrophilic, basic, and acidic compounds.

column-to-column

YMC controls packing condition under stringent quality control criteria. That is because YMC provides columns of high theoretical plate number and consistently reproducible quality.

Batch certificates

Batch certificates

Batch certificates show basic properties of raw material silica gel such as particle size, pore size and metal content.
Carbon load after bonding and results of a separation with standard test mixture are shown.

Column inspection reports

Column inspection reports

Columns inspection reports that show column quality such as theoretical plate number and asymmetry factor are also shown. All analysis conditions including the sample concentration are shown so the analyst may periodically use the same conditions to evaluate column degradation.

Attached batch certificates and column inspection reports prove batch-to-batch and column-to- column reproducibility.

2 μm perticle size columns included in Pro C18 can be used for ultra fast analysis with conventional LC, as its pressure is lower than commercial sub-2 μm columns. Considering the extra column band broadening, the column of 3.0 mmI.D. is more applicable for conventional LC systems than the column of 2.0 mmI.D..

50 X 3.0 mmI.D. / 50 X 2.0 mmI.D.

Cephalosporin antibiotics

1. Cephalexin
2. Cefaclor
3. Cephaloglycin
4. Cephaloridine

Technical data